Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
7705831 | International Journal of Hydrogen Energy | 2018 | 11 Pages |
Abstract
In this study, an electrolyser was used to supply hydrogen to the SI engine. Firstly, the appropriate operation point for the electrolyser was determined by adjusting the amount of KOH in the electrolyte to 5%, 10%, 20% and 30% by mass, and applying 12Â V, 16Â V, 20Â V, 24Â V and 28Â V voltages. Tests were first carried out with the gasoline without the use of an electrolyser, followed by operating the electrolyser at the appropriate point and sending obtained H2 and O2 to the engine in addition to the gasoline. The SI engine was operated between 2500Â rpm and 3500Â rpm engine speeds with and without hydrogen addition. Cylinder pressure, the amount of gasoline, H2 and O2 consumed by the engine and the emission data were collected from the test system at the aforementioned engine speeds. Furthermore, indicated engine torque, indicated specific energy consumption, specific emissions and HRR values were calculated. According to the results obtained, improvement in ISEC values was observed, and CO and THC values were improved by up to 21.3% and 86.1% respectively. Even though the dramatic increase in NOx emissions cannot be averted, they can be controlled by equipment such as EGR three-way catalytic converter.
Related Topics
Physical Sciences and Engineering
Chemistry
Electrochemistry
Authors
Yasin Karagöz, Ãzgün Balcı, Emre Orak, Mostafa S. Habib,