| Article ID | Journal | Published Year | Pages | File Type |
|---|---|---|---|---|
| 7707916 | International Journal of Hydrogen Energy | 2018 | 13 Pages |
Abstract
The equations governing the electrochemical processes, the energy and the exergy balances of the power plant components are established. Numerical simulation using EES software is performed. The influences of key operating parameters, such as humidity, pre-reforming fraction, extraction fraction from the Gas Turbine and fuel utilization on the performances of the SOFC-GT hybrid system are analyzed. Obtained results show that the integration of the SOFC enhances significantly the hybrid overall cycle efficiency. The increase of the ambient temperature and humidity reduces the system efficiencies. The utilization factor has a negative effect on the SOFC temperature and voltage. That leads to a decrease in the power plant performances. While the pre-reforming fraction, has a positive effect on the indicated parameters.
Related Topics
Physical Sciences and Engineering
Chemistry
Electrochemistry
Authors
Salha Faleh Sghaier, Tahar Khir, Ammar Ben Brahim,