Article ID Journal Published Year Pages File Type
7719220 International Journal of Hydrogen Energy 2014 10 Pages PDF
Abstract
In the present study, the energy and exergy analysis were carried out for a Deutz dual fuel (diesel + hydrogen) engine at different gas fuel-air ratios (øH2 = 0.3, 0.4, 0.5, 0.6, 0.7, and 0.8) and constant diesel fuel amount (6.48 mg/cycle). The energy analysis was performed during a closed cycle by using a three-dimensional CFD code and combustion modeling was carried out by Extend Coherent Flame Model- Three Zone model (ECFM-3Z). For the exergy analysis, an in-house computational code is developed, which uses the results of the energy analysis at different fuel-air ratios. The cylinder pressure results for natural gas/diesel fuelled engine are verified with the experimental data in the literature, which shows a good agreement. This verification gives confidence in the model prediction for hydrogen- fuelled case. With crank position at different gas fuel-air ratios, various rate and cumulative exergy components are identified and calculated separately. It is found that as gas fuel-air ratio increases from 0.3 to 0.8, the exergy efficiency decreases from 43.7% to 34.5%. Furthermore, the value of irreversibility decreases from 29.8% to 26.6% of the mixture fuels chemical exergies. These values are in good agreement with data in the literature for dual fuel engines.
Related Topics
Physical Sciences and Engineering Chemistry Electrochemistry
Authors
,