This technique is developed for dynamic high-resolution CT scanning or 4D-μCT, a tool to study dynamic processes in situ on the micro-scale. We propose to start from the low quality reconstruction and perform a piecewise linear fit in the time direction for each voxel. This effectively uses the nearby temporal information, regardless of the nature of the dynamic process, without introducing spatial correlation.
Related Topics
Physical Sciences and Engineering
Materials Science
Materials Science (General)
Authors
Marjolein Heyndrickx, Matthieu Boone, Thomas De Schryver, Tom Bultreys, Wannes Goethals, Glenn Verstraete, Valérie Vanhoorne, Luc Van Hoorebeke,