Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
8174646 | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | 2015 | 6 Pages |
Abstract
A reliable voltage reference is mandatory in mixed-signal systems. However, this family of components can undergo very long single event transients when operating in radiation environments such as space and nuclear facilities due to the impact of heavy ions. The purpose of the present paper is to demonstrate how a simple cell can be used to detect these transients. The cell was implemented with typical COTS components and its behavior was verified by SPICE simulations and in a laser facility. Different applications of the cell are explored as well.
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Instrumentation
Authors
F.J. Franco, C. Palomar, J.G. Izquierdo, J.A. Agapito,