Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
8208663 | Applied Radiation and Isotopes | 2018 | 8 Pages |
Abstract
To minimize the size and weight of a vehicle-mounted accelerator-driven D-T neutron source and protect workers from unnecessary irradiation after the equipment shutdown, a method to optimize radiation shielding material aiming at compactness, lightweight, and low activation for the fast neutrons was developed. The method employed genetic algorithm, combining MCNP and ORIGEN codes. A series of composite shielding material samples were obtained by the method step by step. The volume and weight needed to build a shield (assumed as a coaxial tapered cylinder) were adopted to compare the performance of the materials visually and conveniently. The results showed that the optimized materials have excellent performance in comparison with the conventional materials. The “MCNP6-ACT” method and the “rigorous two steps” (R2S) method were used to verify the activation grade of the shield irradiated by D-T neutrons. The types of radionuclide, the energy spectrum of corresponding decay gamma source, and the variation in decay gamma dose rate were also computed.
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Radiation
Authors
Yao Cai, Huasi Hu, Shuangying Lu, Qinggang Jia,