Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
8941940 | Applied Thermal Engineering | 2018 | 22 Pages |
Abstract
Various incipient boiling heat fluxes and transient heat transfer coefficients of nucleate boiling on a horizontal heated cylinder in liquid D-mannitol were measured. A platinum cylinder was used as a heater in the experiment. The diameter and effective length of the platinum cylinder were 1.0 and 25.9â¯mm, respectively. The cylinder was heated by a DC power supply until the nucleate boiling regime in liquid D-mannitol was reached. The temperature of the liquid D-mannitol ranged from 455 to 502â¯K. The e-folding time of the heat generation rate ranged from 0.35 to 19â¯s. The incipient boiling heat flux was dependent on the e-folding time of the heat generation rate, whereas the transient nucleate boiling heat transfer was not affected by the e-folding time of the heat generation rate. From the experimental data, the correlations of the incipient heat flux and the transient heat transfer coefficient were obtained.
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Fluid Flow and Transfer Processes
Authors
M. Shibahara, K. Fukuda, Q.S. Liu,