Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
9743301 | Analytica Chimica Acta | 2005 | 8 Pages |
Abstract
Alkyl benzenes and aromatic alcohols were used as model analytes in a chromatographic separation on a new type of hybrid C18 stationary phase. The stationary phase was characterized from the point of view of its interaction with the mentioned analytes. The thermodynamic parameters such as ÎH° and ÎS° showed that there are very few differences in the interactions of the alkyl benzenes and aromatic alcohols with the stationary phase in the temperature interval from 150 to 200 °C. A temperature study in the range from 30 to 200 °C using toluene as an analyte revealed that the van't Hoff plot is non-linear. Differential scanning calorimetry studies on this stationary phase indicated a phase transition at â¼90 °C. Studies on the influence of organic modifier concentrations indicated that the retention of the analytes at 150 °C varied linearly with the volume fraction of acetonitrile in the mobile phase. At 150 °C the van Deemter plot showed that a minimum was reached for the reduced plate height at â¼1.6 mL/min which was constant up to 5 mL/min. A 1-month stability study of the column using pure water as a mobile phase, at 200 °C indicated that analyte retention factor changed by 10% during this period of time.
Related Topics
Physical Sciences and Engineering
Chemistry
Analytical Chemistry
Authors
Y. Liu, N. Grinberg, K.C. Thompson, R.M. Wenslow, U.D. Neue, D. Morrison, T.H. Walter, J.E. O'Gara, K.D. Wyndham,