Article ID Journal Published Year Pages File Type
9759369 International Journal of Hydrogen Energy 2005 12 Pages PDF
Abstract
The feasibility of a stand-alone hybrid wind-photovoltaic (PV) system incorporating compressed hydrogen gas storage was studied for Cooma (Australia). Cooma has an average annual solar and wind energy availability of 1784 and 932kWh/m2, respectively. A system with 69kWhe/day (load) and 483kWhe(storage) was studied. Hydrogen is generated in electrolysers using excess electricity from the system. The system components were selected according to their availability and cost. The “discounted cash flow” method, with the “levelized energy cost” (LEC) as a financial indicator was used for analysis. Configurations with PV% of 100, 60, 12 and zero were analysed. The lowest LEC of AU $2.52/kWhe was found for 100% PV. The cost of hydrogen generation from 100% PV was AU $692/GJ of hydrogen. Fifty-two percent of the total project costs were due to the electrolyser. Hence, a reduction in the electrolyser cost would reduce the cost of the overall system.
Related Topics
Physical Sciences and Engineering Chemistry Electrochemistry
Authors
, , ,