Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
10892930 | Theriogenology | 2012 | 5 Pages |
Abstract
Slush nitrogen (SN2) is a mixture of solid nitrogen and liquid nitrogen, with an average temperature of â207 °C. To investigate whether plunging a French plastic straw (commonly used for sperm cryopreservation) in SN2 substantially increases cooling rates with respect to liquid nitrogen (LN2), a numerical simulation of the heat conduction equation with convective boundary condition was used to predict cooling rates. Calculations performed using heat transfer coefficients in the range of film boiling confirmed the main benefit of plunging a straw in slush over LN2 did not arise from their temperature difference (â207 vs. â196 °C), but rather from an increase in the external heat transfer coefficient. Numerical simulations using high heat transfer (h) coefficients (assumed to prevail in SN2) suggested that plunging in SN2 would increase cooling rates of French straw. This increase of cooling rates was attributed to a less or null film boiling responsible for low heat transfer coefficients in liquid nitrogen when the straw is placed in the solid-liquid mixture or slush. In addition, predicted cooling rates of French straws in SN2 tended to level-off for high h values, suggesting heat transfer was dictated by heat conduction within the liquid filled plastic straw.
Keywords
Related Topics
Life Sciences
Agricultural and Biological Sciences
Animal Science and Zoology
Authors
M. Sansinena, M.V. Santos, N. Zaritzky, J. Chirife,