Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
10974994 | Journal of Dairy Science | 2013 | 6 Pages |
Abstract
A simple, precise, accurate, and validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of dicyandiamide residue in infant formula samples. Following microwave-assisted extraction with 5% formic acid and clean-up on a Sep-Pak AC-2 SPE cartridge, samples were separated on a ZIC-HILIC HPLC column (150 Ã 2.1 mm i.d., 5-µm film thickness; Merck KGaA, Darmstadt, Germany) with 20 mM ammonium acetate solution-acetonitrile as mobile phase at a flow rate of 0.25 mL/min. A linear calibration curve was obtained in the concentration range from 1.0 to 50 ng/mL. Infant formula samples were fortified with dicyandiamide at 3 levels, producing average recovery yields of 83.6 to 95.7%. The limits of detection and quantification of dicyandiamide were 3 and 10 μg/kg, respectively. Due to its simplicity and accuracy, the straightforward method is particularly suitable for routine dicyandiamide detection.
Keywords
Related Topics
Life Sciences
Agricultural and Biological Sciences
Animal Science and Zoology
Authors
Yan Shen, Chao Han, Xiujin Zhou, Xiangzhun Chen, Fuzhen Huang, Zhenou Zhu,