Article ID Journal Published Year Pages File Type
1285238 Journal of Power Sources 2009 7 Pages PDF
Abstract

Tubular microbial fuel cells (MFC) with air cathode might be amenable to scale-up but with increasing volume a mechanically robust, cost-effective cathode structure is required. Membrane electrode assemblies (MEA) are investigated in a tubular MFC using cost-effective cation (CEM) or anion (AEM) exchange membrane. The MEA fabrication mechanically combines a cathode electrode with the membrane between a perforated cylindrical polypropylene shell and tube. Hydrogel application between membrane and cathode increases cathode potential by ∼100 mV over a 0–5.5 mA range in a CEM-MEA. Consequently, 6.1 W m−3 based on reactor liquid volume (200 cm3) are generated compared with 5 W m−3 without hydrogel. Cathode potential is also improved in AEM-MEA using hydrogel. Electrochemical Impedance Spectroscopy (EIS) to compare MEA's performance suggests reduced impedance and enhanced membrane–cathode contact area when using hydrogel. The maximum coulombic efficiency observed with CEM-MEA is 71% and 63% with AEM-MEA. Water loss through the membrane varies with external load resistance, indicating that total charge transfer in the MFC is related to electro-osmotic drag of water through the membrane. The MEA developed here has been shown to be mechanically robust, operating for more than six month at this scale without problem.

Related Topics
Physical Sciences and Engineering Chemistry Electrochemistry
Authors
, , , , ,