Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1285962 | Journal of Power Sources | 2007 | 4 Pages |
Abstract
A Li-ion polymer pouch cell battery design for a spacesuit developed an internal short during ground storage. A detailed failure investigation found that native contamination was the most probable root cause as the failure mechanism was successfully replicated. Lessons learned are applicable to the implementation of most Li-ion cell designs for critical applications.
Keywords
Related Topics
Physical Sciences and Engineering
Chemistry
Electrochemistry
Authors
Eric Darcy,