Article ID Journal Published Year Pages File Type
4507102 Crop Protection 2010 10 Pages PDF
Abstract

Two different spray application methods were compared in three vine varieties at different crop stages. A conventional spray application with a constant volume rate per unit ground area (l ha−1) was compared with a variable rate application method designed to compensate electronically for measured variations in canopy dimensions. An air-blast sprayer with individual multi-nozzle spouts was fitted with three ultrasonic sensors and three electro valves on one side, in order to modify the emitted flow rate of the nozzles according to the variability of canopy dimensions in real time. The purpose of this prototype was to precisely apply the required amount of spray liquid and avoid over dosing. On average, a 58% saving in application volume was achieved with the variable rate method, obtaining similar or even better leaf deposits.

Related Topics
Life Sciences Agricultural and Biological Sciences Agronomy and Crop Science
Authors
, , , ,