Article ID Journal Published Year Pages File Type
547595 Microelectronics Reliability 2007 5 Pages PDF
Abstract

IGBT with sense emitter cells are used in power applications where current sensing or feedback is needed to guarantee safe operation of the switching device. In this paper we show, by experimental measurements and simulations, how the coupling of undesired voltages to the sense cell that is disconnected from the main IGBT emitter is able to trigger the latch-up of the entire device during inductive switching leading to its failure. Being able to reproduce the failure phenomenon by 2D simulations we are able to identify the possible physical cause of this phenomenon.

Related Topics
Physical Sciences and Engineering Computer Science Hardware and Architecture
Authors
, , , , , , ,