Article ID Journal Published Year Pages File Type
6301289 Ecological Engineering 2016 6 Pages PDF
Abstract
The stability and serviceability of geotechnical infrastructure may be affected by plant-induced soil suction during drying-wetting cycles, because an increase in suction would reduce hydraulic conductivity and also increase shear strength. Recent studies have been conducted to quantify suction induced during evapotranspiration (ET) and ponding in soil vegetated with non-crop species that are used for the ecological restoration of geotechnical infrastructure. However, induced suction distribution under drying-wetting cycles is rarely studied. The objectives of this study are to (1) quantify suction induced by a non-crop tree species, Schefflera heptaphylla, under ponding-drying-ponding cycles and (2) correlate intercepted radiant energy, tree leaf area index (LAI), extinction coefficient (k) and root area index (RAI) with suction. In total, 18 vegetated soil samples with LAI ranging from 0.9 to 3.1 and three bare soil samples (control) were tested and subjected to identical cycles of ET and ponding. Energy balance calculation was performed to determine the percentage of interception of radiant energy. An almost linear relationship can be seen between the percentage of energy intercepted (from 7% to 42% ± 4%) and LAI (from 0.9 to 3.1 ± 0.09) for S. heptaphylla. The measured value of k for S. heptaphylla (0.13) was found to be much lower than that of some crop species (0.4-1.6) reported in the literature. Peak suction is always identified at the depth, where RAI is maximum. It was further demonstrated that the tree-induced suction has a strong linear correlation with both the RAI and LAI.
Related Topics
Life Sciences Agricultural and Biological Sciences Ecology, Evolution, Behavior and Systematics
Authors
, , , ,