Article ID Journal Published Year Pages File Type
6381256 Aquacultural Engineering 2016 17 Pages PDF
Abstract
The internal flow velocities and external flow patterns for different SBCC container designs were measured and used to inform design decisions. Suitable graphical representations have been developed to assess SBCC containers on specific performance criteria. Oyster SBCC containers were found to provide stable motion characteristics but perform poorly against the lower velocity limit, indicating insufficient supply of Dissolved Oxygen (DO) to allow for optimal growth of European lobsters. Internal flow velocities were also measured on un-fouled and fouled SBCC containers; results showed SBCC 2 would not provide enough DO with 66% biofouling coverage (66% biofouling replicates one year deployment) and triggered a redesign. SBCC 1 at 90° yaw angle of attack demonstrated all round good performance against upper and lower velocity limits and motion characteristics; thus showed greatest promise for cultivation of European Lobster.
Related Topics
Life Sciences Agricultural and Biological Sciences Aquatic Science
Authors
, , ,