Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
6946150 | Microelectronics Reliability | 2017 | 5 Pages |
Abstract
This problem is discussed here based on the practical example of an air cooled power device operating at different power dissipation levels and in variable cooling conditions. The experiments presented in this paper demonstrate that the notion of junction-to-case thermal resistance is ambiguous since the cooling conditions affect the heat diffusion processes inside the package and consequently influence the thermal resistance value. For the analysed device, a simple four-stage RC Foster ladder model is proposed here to simulate the device dynamic thermal behaviour. Owing to the fact that this model is generated in a structure preserving way, its element values can be assigned some physical meaning.
Related Topics
Physical Sciences and Engineering
Computer Science
Hardware and Architecture
Authors
Marcin Janicki, Tomasz Torzewicz, Agnieszka Samson, Tomasz Raszkowski, Artur Sobczak, Mariusz Zubert, Andrzej Napieralski,