Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
6946213 | Microelectronics Reliability | 2017 | 5 Pages |
Abstract
Glass transition temperature (Tg) is a key epoxy property and often being monitored in the production by the differential scanning calorimeter (DSC) method in the printed circuit board (PCB) industry. The dual-effect of cooling rate and annealing on the endothermic peak in the DSC scan of CE-688 epoxy resin plays a big role in the DSC Tg evaluation. An improved DSC program was developed in order to minimize/eliminate the influence of endothermic peak. Meanwhile, the curing pressure also shows distinct effect on the Tg of the epoxy resin.
Related Topics
Physical Sciences and Engineering
Computer Science
Hardware and Architecture
Authors
Qi Tao, Gerald Pinter, Thomas Krivec,