Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
7727085 | Journal of Power Sources | 2016 | 10 Pages |
Abstract
In this work, we develop a two-dimensional, transient model to investigate the mechanisms of ion-transport through a porous separator in VRFBs and their effects on battery performance. Commercial-available separators with pore sizes of around 45Â nm are particularly investigated and effects of key separator design parameters and operation modes are explored. We reveal that: i) the transport mechanism of vanadium-ion crossover through available separators is predominated by convection; ii) reducing the pore size below 15Â nm effectively minimizes the convection-driven vanadium-ion crossover, while further reduction in migration- and diffusion-driven vanadium-ion crossover can be achieved only when the pore size is reduced to the level close to the sizes of vanadium ions; and iii) operation modes that can affect the pressure at the separator/electrode interface, such as the electrolyte flow rate, exert a significant influence on the vanadium-ion crossover rate through the available separators, indicating that it is critically important to equalize the pressure on each half-cell of a power pack in practical applications.
Related Topics
Physical Sciences and Engineering
Chemistry
Electrochemistry
Authors
X.L. Zhou, T.S. Zhao, L. An, Y.K. Zeng, L. Wei,