Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
7742505 | Journal of Power Sources | 2012 | 8 Pages |
Abstract
⺠The thermal regenerative unit recovers the heat dissipated by the stack. ⺠A thermostat valve has optimized the stack operation temperature. ⺠The effectiveness of the planar heat exchanger rounds 100% in the steady state. ⺠The thermal efficiency of the fuel cell cogeneration system is about 20 ± 8%. ⺠The overall efficiency of the cogeneration system is as high as 75% at PL = 2.5 kW and TR = 54 °C.
Related Topics
Physical Sciences and Engineering
Chemistry
Electrochemistry
Authors
Jenn-Jiang Hwang,