Article ID Journal Published Year Pages File Type
8494219 Aquaculture 2016 6 Pages PDF
Abstract

- Verify the optimal AC frequency range for industrial electro stunning by investigating the electrical impedance spectra.
- The maximum average impedance value was found at 100 Hz, individual peak values from 70-100 Hz.
- Due to measured impedance values it is concluded that the optimal range for electro stunning Atlantic salmon is 70 to 100 Hz.
- The highest impedance measurements are found in the range from 60 to 800 Hz, which are well suited for electro stunning.
- The measured electrical impedance indicating that 50 Hz to 1 kHz is an acceptable frequency range for electro stunning.