Article ID Journal Published Year Pages File Type
4366316 International Journal of Food Microbiology 2016 11 Pages PDF
Abstract

•A cross contamination model was challenged and evaluated applying a new approach.•QMRA and Total Transfer Potential (TTP) were included.•Transfer estimates were not applicable for unlike processing.•The risk of disease may be reduced when using a stainless steel grinder.•Well-sharpened knife, and room temperatures lower than 4 °C can be beneficial.

In a previous study, a model was developed to describe the transfer and survival of Salmonella during grinding of pork (Møller, C.O.A., Nauta, M.J., Christensen, B.B., Dalgaard, P., Hansen, T.B., 2012. Modelling transfer of Salmonella typhimurium DT104 during simulation of grinding of pork. Journal of Applied Microbiology 112 (1), 90–98). The robustness of this model is now evaluated by studying its performance for predicting the transfer and survival of Salmonella spp. and Listeria monocytogenes during grinding of different types of meat (pork and beef), using two different grinders, different sizes and different numbers of pieces of meats to be ground. A total of 19 grinding trials were collected. Acceptable Simulation Zone (ASZ), visual inspection of the data, Quantitative Microbiological Risk Assessment (QMRA), as well as the Total Transfer Potential (TTP) were used as approaches to evaluate model performance and to access the quality of the cross contamination model predictions. Using the ASZ approach and considering that 70% of the observed counts have to be inside a defined acceptable zone of ± 0.5 log10CFU per portion, it was found that the cross contamination parameters suggested by Møller et al. (2012) were not able to describe all 19 trials. However, for each of the collected grinding trials, the transfer event was well described when fitted to the model structure proposed by Møller et al. (2012). Parameter estimates obtained by fitting observed trials performed at different conditions, such as size and number of pieces of meat to be ground, may not be applied to describe cross contamination of unlike processing. Nevertheless, the risk estimates, as well as the TTP, revealed that the risk of disease may be reduced when the grinding of meat is performed in a grinder made of stainless steel (for all surfaces in contact with the meat), using a well-sharpened knife and holding at room temperatures lower than 4 °C.

Related Topics
Life Sciences Agricultural and Biological Sciences Food Science
Authors
, , , , , , , , , , , ,