Article ID Journal Published Year Pages File Type
541634 Microelectronic Engineering 2009 5 Pages PDF
Abstract
In the present paper, we propose a novel method for measuring the even aberrations of lithographic projection optics by use of optimized phase-shifting marks on the test mask. The line/space ratio of the phase-shifting marks is optimized to obtain the maximum sensitivities of Zernike coefficients corresponding to even aberrations. Spherical aberration and astigmatism can be calculated from the focus shifts of phase-shifting gratings oriented at 0°, 45°, 90° and 135° at multiple illumination settings. The PROLITH simulation results show that, the measurement accuracy of spherical aberration and astigmatism obviously increase, after the optimization of the measurement mark.
Related Topics
Physical Sciences and Engineering Computer Science Hardware and Architecture