کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
10977994 1108054 2013 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
An automated walk-over weighing system as a tool for measuring liveweight change in lactating dairy cows
ترجمه فارسی عنوان
خودکار سیستم پیاده روی بیش از حد به عنوان ابزار برای اندازه گیری تغییرات وزن زنده در گاو شیرده
کلمات کلیدی
لبنیات، گاو وزن، مقیاس،
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم کشاورزی و بیولوژیک علوم دامی و جانورشناسی
چکیده انگلیسی
Automated walk-over weighing systems can be used to monitor liveweights of cattle. Minimal literature exists to describe agreement between automated and static scales, and no known studies describe repeatability when used for daily measurements of dairy cows. This study establishes the repeatability of an automated walk-over cattle-weighing system, and agreement with static electronic scales, when used in a commercial dairy herd to weigh lactating cows. Forty-six lactating dairy cows from a seasonal calving, pasture-based dairy herd in southwest Victoria, Australia, were weighed once using a set of static scales and repeatedly using an automated walk-over weighing system at the exit of a rotary dairy. Substantial agreement was observed between the automated and static scales when assessed using Lin's concordance correlation coefficient. Weights measured by the automated walkover scales were within 5% of those measured by the static scales in 96% of weighings. Bland and Altman's 95% limits of agreement were −23.3 to 43.6 kg, a range of 66.9 kg. The 95% repeatability coefficient for automated weighings was 46.3 kg. Removal of a single outlier from the data set increased Lin's concordance coefficient, narrowed Bland and Altman's 95% limits of agreement to a range of 32.5 kg, and reduced the 95% repeatability coefficient to 18.7 kg. Cow misbehavior during walk-over weighing accounted for many of the larger weight discrepancies. The automated walk-over weighing system showed substantial agreement with the static scales when assessed using Lin's concordance correlation coefficient. This contrasted with limited agreement when assessed using Bland and Altman's method, largely due to poor repeatability. This suggests the automated weighing system is inadequate for detecting small liveweight differences in individual cows based on comparisons of single weights. Misbehaviors and other factors can result in the recording of spurious values on walk-over scales. Excluding outlier weights and comparing means of 7 consecutive daily weights may improve agreement sufficiently to allow meaningful assessment of small short-term changes in automated weights in individuals and groups of cows.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Dairy Science - Volume 96, Issue 7, July 2013, Pages 4477-4486
نویسندگان
, , , , , , ,