Pitfalls in microcystin extraction and recovery from human blood serum
ترجمه فارسی عنوان
مشکلات در استخراج میکروسستین و بازیابی سرم خون انسان
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم محیط زیست بهداشت، سم شناسی و جهش زایی
چکیده انگلیسی


• The Adda-ELISA is suitable for the detection of MCs in human blood serum.
• The ELISA detected MC-LR, -YR, -RR, -LA, -LW, -LF and defined mixtures thereof.
• Potential pitfalls of the MC-extraction method were identified.
• MC’s adhesion to surface is highly related to its hydrophobicity.
• A solution to the problem is provided.

BackgroundMicrocystins (MCs) contaminate water bodies due to cyanobacterial blooms all over the world, leading to frequent exposure of humans to MCs through consumption of meat, fish, seafood, blue-green algal products and water, accidental ingestion of contaminated water and scum during recreational activities and inhalation of cyanobacterial aerosols. For monitoring of human exposure, sensitive screening methods are needed. However, during the analytical process of various matrices, such as human serum, some problems appear to regularly occur during sample preparation and storage, leading to MC loss and thus to underestimation of the true MC concentration. The aim of the current study was therefore to assess the pitfalls of the MC-extraction method from human serum with more detail.MethodsSix MC congeners (MC-LR, -YR, -RR, -LA, -LW, -LF) and defined equimolar MC mixtures thereof were spiked into human serum, and quantified using the commercially available Adda-ELISA subsequent to standard extraction (methanol extraction with subsequent SPE). To detect the potential influence of sample storage and preparation/storage materials, different types of material such as glass, standard polypropylene and surface-treated polypropylene were compared.ResultsLoss of MC during preparation and storage is largely dependent on (1) the handling of the stored material, (2) the ‘surface’ of the storage material and (3) the hydrophobicity of the MCs.ConclusionsThe pitfalls described for MC analysis with the ELISA are primarily associated with sample preparation and clean-up and thus also apply to other analytical techniques for MC detection beyond the ELISA used. It can be concluded that ELISA-based methods are suitable tools for the detection of MCs in human sera and other samples.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Chemico-Biological Interactions - Volume 223, 5 November 2014, Pages 87–94
نویسندگان
, , , , ,