کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2983770 1578659 2010 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Effects on pre- and posttransplant pulmonary hemodynamics in patients with continuous-flow left ventricular assist devices
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Effects on pre- and posttransplant pulmonary hemodynamics in patients with continuous-flow left ventricular assist devices
چکیده انگلیسی

ObjectivePulsatile left ventricular assist devices have been shown to effectively reduce pulmonary hypertension in patients with end-stage heart failure. However, it remains to be seen whether newer continuous-flow left ventricular assist devices have a similar effect on pulmonary hypertension. The objective of this study was to determine whether the HeartMate II (Thoratec Corp, Pleasanton, Calif), a continuous-flow left ventricular assist device, is effective in improving pulmonary hemodynamics in the period after left ventricular assist device support and posttransplant.MethodsFifty patients with end-stage heart failure underwent HeartMate II left ventricular assist device placement as a bridge to transplant. We evaluated their pulmonary hemodynamics with right-sided heart catheterization at baseline, after left ventricular assist device placement, and after heart transplant.ResultsThe mean age of patients was 53.7 ± 13.5 years. Ischemic etiology was present in 60% of the patients. After left ventricular assist device placement (mean duration, 135 ± 60 days), mean systolic and diastolic pulmonary artery pressures decreased significantly from a baseline of 55.2 ± 13.4 mm Hg and 27.3 ± 6.8 mm Hg, respectively, to 35.9 ± 10.8 mm Hg and 15.8 ± 6.5 mm Hg, respectively (P < .001). Similarly, mean pulmonary vascular resistance decreased significantly from a baseline of 3.6 ± 1.9 Woods units to 2.1 ± 0.8 Woods units (P < .001). Posttransplant pulmonary hemodynamics also remained within normal limits, even in patients with previously severe pulmonary hypertension.ConclusionContinuous-flow left ventricular assist devices effectively improve pulmonary hemodynamics associated with end-stage heart failure. Moreover, pulmonary hemodynamics remain within normal limits in the posttransplant period, even in patients with severe pulmonary hypertension. Therefore, adequate left ventricular decompression achieved with newer left ventricular assist devices can reverse significant pulmonary hypertension in patients with end-stage heart failure, making them eligible for cardiac transplantation.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Thoracic and Cardiovascular Surgery - Volume 140, Issue 2, August 2010, Pages 447–452
نویسندگان
, , , , , ,