کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3075309 1580963 2014 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Automated cerebellar segmentation: Validation and application to detect smaller volumes in children prenatally exposed to alcohol
ترجمه فارسی عنوان
تقسیم بندی مخروطی خودکار: اعتبار سنجی و کاربرد آن برای تشخیص حجم کمتری در کودکان مبتلا به الکل است
موضوعات مرتبط
علوم زیستی و بیوفناوری علم عصب شناسی روانپزشکی بیولوژیکی
چکیده انگلیسی


• Cerebellum is automatically segmented using active appearance modeling.
• Excellent reliability and validity of automated vs. manual measurements
• Cerebellum is automatically segmented in children prenatally exposed to alcohol.
• Automated cerebellar measures are smaller in children prenatally exposed to alcohol.
• Prenatal alcohol results are consistent with prior studies using manual labeling.

ObjectiveTo validate an automated cerebellar segmentation method based on active shape and appearance modeling and then segment the cerebellum on images acquired from adolescents with histories of prenatal alcohol exposure (PAE) and non-exposed controls (NC).MethodsAutomated segmentations of the total cerebellum, right and left cerebellar hemispheres, and three vermal lobes (anterior, lobules I–V; superior posterior, lobules VI–VII; inferior posterior, lobules VIII–X) were compared to expert manual labelings on 20 subjects, studied twice, that were not used for model training. The method was also used to segment the cerebellum on 11 PAE and 9 NC adolescents.ResultsThe test–retest intraclass correlation coefficients (ICCs) of the automated method were greater than 0.94 for all cerebellar volume and mid-sagittal vermal area measures, comparable or better than the test–retest ICCs for manual measurement (all ICCs > 0.92). The ICCs computed on all four cerebellar measurements (manual and automated measures on the repeat scans) to compare comparability were above 0.97 for non-vermis parcels, and above 0.89 for vermis parcels. When applied to patients, the automated method detected smaller cerebellar volumes and mid-sagittal areas in the PAE group compared to controls (p < 0.05 for all regions except the superior posterior lobe, consistent with prior studies).DiscussionThese results demonstrate excellent reliability and validity of automated cerebellar volume and mid-sagittal area measurements, compared to manual measurements. These data also illustrate that this new technology for automatically delineating the cerebellum leads to conclusions regarding the effects of prenatal alcohol exposure on the cerebellum consistent with prior studies that used labor intensive manual delineation, even with a very small sample.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: NeuroImage: Clinical - Volume 4, 2014, Pages 295–301
نویسندگان
, , , , , , ,