Effect of imaging powder and CAD/CAM stone types on the marginal gap of zirconia crowns
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی دندانپزشکی، جراحی دهان و پزشکی
پیش نمایش صفحه اول مقاله
Effect of imaging powder and CAD/CAM stone types on the marginal gap of zirconia crowns
چکیده انگلیسی

ObjectiveTo compare the marginal gap using different types of die stones and titanium dies with and without powders for imaging.MethodsA melamine tooth was prepared and scanned using a laboratory 3-shape scanner to mill a polyurethane die, which was duplicated into different stones (Jade, Lean, CEREC) and titanium. Each die was sprayed with imaging powders (NP, IPS, Optispray, Vita) to form 15 groups. Ten of each combination of stone/titanium and imaging powders were used to mill crowns. A light-bodied impression material was injected into the intaglio surface of each crown and placed on the corresponding die. Each crown was removed, and the monophase material was injected to form a monophase die, which was cut into 8 sections. Digital images were captured using a stereomicroscope to measure marginal gap. Scanning electron microscopy was used to determine the particle size and shape of imaging powders and stones.ResultsMarginal gaps ranged from mean (standard deviation) 49.32 to 91.20 micrometers (3.97-42.41 μm). There was no statistical difference (P > .05) in the marginal gap by any combination of stone/titanium and imaging powders. All of the imaging powders had a similar size and rounded shape, whereas the surface of the stones showed different structures.ConclusionsWhen a laboratory 3-shape scanner is used, all imaging powders performed the same for scanning titanium abutments. However, there was no added value related to the use of imaging powder on die stone. It is recommended that the selection of stone for a master cast be based on the physical properties.Practical ImplicationsWhen a laboratory 3-shape scanner is used, the imaging powder is not required for scanning die stone. Whenever scanning titanium implant abutments, select the least expensive imaging powder.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of the American Dental Association - Volume 146, Issue 2, February 2015, Pages 111–120
نویسندگان
, , , , , , ,