Mineral Trioxide Aggregate–based Sealer: Analysis of Tissue Reactions to a New Endodontic Material
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی دندانپزشکی، جراحی دهان و پزشکی
پیش نمایش صفحه اول مقاله
Mineral Trioxide Aggregate–based Sealer: Analysis of Tissue Reactions to a New Endodontic Material
چکیده انگلیسی

IntroductionThe aim of this study was to evaluate the subcutaneous connective tissue reaction to mineral trioxide aggregate (MTA)-based sealer (Endo CPM Sealer; CPM Sealer; EGEO SRL, Buenos Aires, Argentina), MTA, and an epoxy resin-based sealer (AH Plus; Dentsply HERO Indústria e Comércio Ltda, Petrópolis, RJ, Brazil).MethodsPolyethylene tubes containing the test materials and empty tubes (control group) were implanted in the subcutaneous tissue of 18 rats. After 7, 30, and 60 days, observations were made for cellular inflammatory components, fibrous condensation, and abscess formation. Comparisons between groups and periods of time were made using the Friedman test and the Kruskall-Wallis test.ResultsLymphocytes and plasmacytes were more intensely observed in the reaction to AH Plus sealer after 30 days (p < 0.05). MTA and the Endo CPM Sealer presented a behavior similar to that of the control group throughout the whole experiment.ConclusionThe Endo CPM Sealer presented biological potential. Characteristics of the inflammatory reaction were equivalent to those produced by MTA.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)