Biomechanical study of unilateral pedicle screw combined with contralateral translaminar facet screw in transforaminal lumbar interbody fusion
ترجمه فارسی عنوان
مطالعه بیومکانیک اسکلتی یکساله ای همراه با اسکلت چهره فراملامین متعارف در همجوشی بین بافت کمر مفصلی
کلمات کلیدی
پیچ پیچ پیچ پدیکل، ترکیب ترانسفورمینال اینترفردی کمری، بیومکانیک
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
چکیده انگلیسی


• UPS + TLFS achieve similar range of motion to BPS after short and long-term loading.
• UPS + TLFS decrease the displacement of contralateral articular surfaces of the facet joint than UPS.
• UPS + TLFS offer the surgeons in their minimally invasive spine procedure an alternative option to BPS.

BackgroundThe biomechanical stability of unilateral pedicle screw (UPS) combined with contralateral translaminar facet screw (TLFS), especially long-term stability, still needs to be compared to traditional UPS or bilateral pedicle screws (BPSs) in details.MethodsTwenty-four porcine spines (L2–L5) were tested for flexibility with pure moments of 5 Nm under intact status and transforaminal lumbar interbody fusion status using UPS + TLFS, UPS or BPS at L3–L4. After short-term (3 cycles) and long-term cyclic loading (18,000 cycles), the range of motion was obtained and analyzed for single-level constructs in flexion/extension, lateral bending and axial rotation modes. In addition, the relative displacement of contralateral articular processes was recorded in a real time fashion.FindingsThe range of motion was significantly reduced in all instrumented constructs. In all movement directions, UPS + TLFS achieved similar range of motion to BPS after short and long-term loading, which were significantly lower than that in UPS. A significantly larger displacement of contralateral articular process was recorded in UPS than UPS + TLFS and BPS during extension/flexion, lateral bending and axial rotation, suggesting its compromised stability.InterpretationThe hybrid construct of UPS + TLFS showed instant and long-term equivalent biomechanical ability to that of traditional BPS, making it an alternative option to BPS that could be less invasive while maintains a stable and effective instrumentation.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Clinical Biomechanics - Volume 30, Issue 7, August 2015, Pages 657–661