کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5767591 1628388 2017 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Matching portable NIRS instruments for in situ monitoring indicators of milk composition
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم کشاورزی و بیولوژیک دانش تغذیه
پیش نمایش صفحه اول مقاله
Matching portable NIRS instruments for in situ monitoring indicators of milk composition
چکیده انگلیسی


- Establishing strategies for on-site milk quality control.
- Monitoring in real-time, in-situ and without pre-treatment milk composition.
- Moving Modified Partial Least Square Calibration models for milk analysis from one to another NIR portable instrument.

The real time knowledge of dairy milk composition can be used as a tool to guarantee milk quality and safety, offering additional information for dairy producers and consumers. To carry out these in situ analyses, methodologies based on Near Infrared (NIR) portable sensors have a great potential as an advisory tool. The main goals of the present work have been to develop a methodology using a hand-held portable NIR spectrophotometer to collect raw milk spectra, including the development of calibration models for the analysis of protein, fat and solids-non-fat (SNF) of raw milk and further to transfer the developed models to another portable unit. A total of 542 fresh milk samples were scanned over the NIR spectral range (1600-2400 nm) using a hand-held MicroPhazir™ (MP) NIR spectrometer and different instrumental configurations. The best results for repeatability and reproducibility calculated as root mean squared (RMS) were obtained using a 17 mm cuvette thickness. The displayed predictive ability of calibration models measured as Standard error of prediction/Standard error of cross validation were 0.96; 0.72 and 0.83 for fat, protein and SNF contents, respectively. For cloning purposes an additional MP unit (satellite) has been used. A standardization set of 10 samples enabled standardization of both instruments. After applying standardization matrix, Standard error of differences between master and satellite reached great reduction, 68% for fat, 66% for protein and 54% for SNF. Moreover, the demonstrated ability of sharing calibration models among several units is essential for implementation of portable instruments for in-situ analysis to provide indicators of milk composition at farm level.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Food Control - Volume 76, June 2017, Pages 74-81
نویسندگان
, , , , , , ,