کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5981386 1177067 2012 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Transfemoral Aortic Valve Replacement With the Edwards SAPIEN and Edwards SAPIEN XT Prosthesis Using Exclusively Local Anesthesia and Fluoroscopic Guidance: Feasibility and 30-Day Outcomes
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Transfemoral Aortic Valve Replacement With the Edwards SAPIEN and Edwards SAPIEN XT Prosthesis Using Exclusively Local Anesthesia and Fluoroscopic Guidance: Feasibility and 30-Day Outcomes
چکیده انگلیسی

ObjectivesThe authors report the feasibility and 30-day outcomes of transfemoral aortic valve replacement (TAVR), using the Edwards SAPIEN (Edwards Lifesciences, Irvine, California) and Edwards SAPIEN XT (Edwards Lifesciences) prosthesis, implanted using exclusively local anesthesia and fluoroscopic guidance.BackgroundTransfemoral TAVR is often managed with general anesthesia. However, a simplified percutaneous approach using local anesthesia has become more popular because it offers multiple advantages in an elderly and fragile population.MethodsBetween May 2006 and January 2011, the authors prospectively evaluated 151 consecutive patients (logistic EuroSCORE: 22.8 ± 11.8%) who underwent TAVR (SAPIEN: n = 78, SAPIEN XT: n = 73) using only local anesthesia and fluoroscopic guidance. The primary endpoint was a combination of all-cause mortality, major stroke, life-threatening bleeding, stage 3 acute kidney injury (AKI), periprocedural myocardial infarction (MI), major vascular complication, and repeat procedure for valve-related dysfunction at 30 days.ResultsTransarterial femoral approach was surgical in all SAPIEN procedures and percutaneous in 97.3% of SAPIEN XT, using the ProStar vascular closure device, and was well tolerated in all cases. Conversion to general anesthesia was required in 3.3% (SAPIEN cases) and was related to complications. Vasopressors were required in 5.5%. Procedural success was 95.4%. The combined-safety endpoint was reached in 15.9%, including overall mortality (6.6%), major stroke (2.0%), life-threatening bleeding (7.9%), stage 3 AKI (0.7%), periprocedural MI (1.3%), major vascular complication (7.9%), and repeat procedure for valve-related dysfunction (2.0%) at 30 days. A permanent pacemaker was required in 5.3%.ConclusionsThis single-center, prospective registry demonstrated the feasibility and safety of a simplified transfemoral TAVR performed using only local anesthesia and fluoroscopic guidance in high surgical risk patients with severe aortic stenosis.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: JACC: Cardiovascular Interventions - Volume 5, Issue 5, May 2012, Pages 461-467
نویسندگان
, , , , , , , , , , , , , , , , ,