کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5992613 1578672 2009 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
The effect of biventricular pacing on cardiac function after weaning from cardiopulmonary bypass in patients with reduced left ventricular function: A pressure-volume loop analysis
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
The effect of biventricular pacing on cardiac function after weaning from cardiopulmonary bypass in patients with reduced left ventricular function: A pressure-volume loop analysis
چکیده انگلیسی

ObjectivePatients with severely reduced left ventricular function undergoing coronary artery bypass grafting have increased complication rates. We hypothesized that temporary postoperative atrial synchronous biventricular pacing would improve left ventricular function after cardiopulmonary bypass.MethodsA left ventricular pressure-volume catheter was placed in 21 patients undergoing coronary artery bypass grafting (ejection fraction 29% ± 5%). Pressure-volume loops were obtained after weaning from cardiopulmonary bypass with atrial synchronous biventricular, left ventricular, and right ventricular outflow tract pacing and atrial-only stimulation at 90 beats/min.ResultsSteady-state systolic and preload-independent parameters were superior for atrial synchronous biventricular and left ventricular pacing and atrial-only pacing relative to atrial synchronous right ventricular outflow tract pacing (P < .05). Diastolic parameters, excepting maximum negative rate of left ventricular pressure change, were unaffected. No significant differences were observed between atrial synchronous biventricular and left ventricular pacing and atrial-only pacing. Systolic dyssynchrony was significantly lower for atrial synchronous biventricular pacing (21% ± 5%), atrial synchronous left ventricular pacing (20% ± 6%), and atrial-only pacing (20% ± 6%) versus atrial synchronous right ventricular outflow tract pacing (25% ± 7%, P < .05). Atrioventricular interval during atrial-only stimulation was positively correlated with difference in stroke work between atrial synchronous biventricular pacing and atrial-only pacing (r2 = 0.78, P > .001).ConclusionPostoperative atrial synchronous biventricular and left ventricular pacing and atrial-only stimulation significantly improve systolic function relative to atrial synchronous right ventricular outflow tract pacing. If atrioventricular conduction is prolonged, atrial synchronous biventricular pacing is preferable to atrial-only pacing.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Thoracic and Cardiovascular Surgery - Volume 138, Issue 1, July 2009, Pages 148-156
نویسندگان
, , , , , , ,