کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5998906 1181455 2012 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Ability of code leaders to recall CPR quality errors during the resuscitation of older children and adolescents
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Ability of code leaders to recall CPR quality errors during the resuscitation of older children and adolescents
چکیده انگلیسی

AimPerformance of high quality CPR is associated with improved resuscitation outcomes. This study investigates code leader ability to recall CPR error during post-event interviews when CPR recording/audiovisual feedback-enabled defibrillators are deployed.Patients and methodsPhysician code leaders were interviewed within 24 h of 44 in-hospital pediatric cardiac arrests to assess their ability to recall if CPR error occurred during the event. Actual CPR quality was assessed using quantitative recording/feedback-enabled defibrillators. CPR error was defined as an overall average event chest compression (CC) rate <95/min, depth <38 mm, ventilation rate >10/min, or any interruptions in CPR >10 s. We hypothesized that code leaders would recall error when it actually occurred ≥75% of the time when assisted by audiovisual alerts from a CPR recording feedback-enabled defibrillators (analysis by χ2).Results810 min from 44 cardiac arrest events yielded 40 complete data sets (actual and interview); ventilation data was available in 24. Actual CPR error was present in 3/40 events for rate, 4/40 for depth, 32/40 for interruptions >10 s, and 17/24 for ventilation frequency. In post-event interviews, code leaders recalled these errors in 0/3 (0%) for rate, 0/4 (0%) for depth, and 19/32 (59%) for interruptions >10 s. Code leaders recalled these CPR quality errors less than 75% of the time for rate (p = 0.06), for depth (p < 0.01), and for CPR interruption (p = 0.04). Quantification of errors not recalled: missed rate error median = 94 CC/min (IQR 93-95), missed depth error median = 36 mm (IQR 35.5-36.5), missed CPR interruption >10 s median = 18 s (IQR 14.4-28.9). Code leaders did recall the presence of excessive ventilation in 16/17 (94%) of events (p = 0.07).ConclusionDespite assistance by CPR recording/feedback-enabled defibrillators, pediatric code leaders fail to recall important CPR quality errors for CC rate, depth, and interruptions during post-cardiac arrest interviews.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Resuscitation - Volume 83, Issue 12, December 2012, Pages 1462-1466
نویسندگان
, , , , , , , , ,