کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6212234 1268575 2014 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Accuracy of fluoroscopically-assisted pedicle screw placement: analysis of 1,218 screws in 198 patients
ترجمه فارسی عنوان
دقت فلوروسکوپی کمک به جای گذاری پیچ پیچ: تجزیه و تحلیل 1،218 پیچ در 198 بیمار
کلمات کلیدی
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
چکیده انگلیسی

Background contextWe retrospectively analyzed a total of 1,218 pedicle screws for accuracy, with postoperative computed tomography (CT), in 198 patients who were operated on between March 2004 and September 2012.PurposeTo determine the incidence of screw misplacement in patients who received a transpedicular screw fixation, with intraoperative fluoroscopy in the lateral and lateral with anteroposterior (AP) positions. The results are compared between the two groups.Study designRetrospective comparative study of accuracy of pedicle screw placement in thoracic and lumbar spine.Patient sampleThe sample consists of 198 consecutive patients who underwent transpedicular screw fixation.Outcome measuresAccuracy of screw placement was evaluated by postoperative CT scan. Misplacement was defined in cases where more than 25% of the screw size was residing outside the pedicle.MethodsThe indications for hardware placement, radiologic studies, patient demographics, and reoperation rates were recorded. Five hundred twenty-eight screws (Group A, n=81) were inserted into the vertebral body with the assistance of lateral fluoroscopy only, whereas 690 screws (Group B, n=117) were inserted with the assistance of lateral fluoroscopy, and the final positions of the screws were checked with AP fluoroscopy.ResultsA total of 1,218 screws were analyzed, with 962 screws placed at the lumbosacral region and 256 screws at the thoracic region. According to the postoperative CT scan, 27 screws (2.2%) were identified as breaching the pedicle. Nineteen of them (3.6%) were in Group A, whereas 8 (1.16%) were in Group B. The rate of pedicle breaches was significantly different between Group A and B (p=.0052). In Group A, the lateral violation of the pedicle was seen in 10 screws (1.9%), whereas medial violation was seen in 9 screws (1.7%). In Group B, the lateral violation of the pedicle was seen in six screws (0.87%), whereas medial violation was seen in two screws (0.29%). The medial and lateral penetration of screws were significantly different between Groups A and B (p<.05). A pedicle breach occurred in 21 patients, and 15 of them underwent a revision surgery to correct the misplaced screw. Of these patients, 11 (13.6%) were in Group A, and 4 (3.4%) were in Group B (p=.0335).ConclusionsIn this study, we evaluated and clarified the diagnostic value of intraoperative fluoroscopy in both the lateral and AP imaging that have not yet been evaluated in any comparative study. We concluded that the intraoperative use of fluoroscopy, especially in the AP position, significantly decreases the risk of screw misplacement and the results are comparable with other advanced techniques.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Spine Journal - Volume 14, Issue 8, 1 August 2014, Pages 1702-1708
نویسندگان
, , , , , ,