Direct coupling of a flow–flow electromembrane extraction probe to LC-MS
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Direct coupling of a flow–flow electromembrane extraction probe to LC-MS
چکیده انگلیسی


• An in-line Electromembrane Extraction – LC-MS system was developed
• Hyphenation of the Electromembrane extraction probe and the LC-MS system was accomplished using a 10-port switching valve
• The system integrates a complete analytical workflow of rapid extraction, enrichment, separation and detection of analytes
• The setup was used to monitor the in-vitro metabolism of methadone by rat liver microsomes

A fully integrated and automated electromembrane extraction LC-MS (EME-LC-MS) system has been developed and characterized. Hyphenation of a flow–flow EME probe to LC-MS was accomplished by using an in-built 10-port switching valve of the LC-MS system. The 10-port switching valve decoupled the high pressure of the UHPLC-system from the low pressure required for operation of the EME-probe by automated switching between a sample extraction/analysis and a sample load position. In the sample load position the extracted analytes were loaded into a HPLC sample loop. By switching the valve to the sample extraction/analysis position the setup allowed simultaneous analysis of previously loaded analytes while extracting a new sample. Performance of the system was characterized with respect to precision and linearity (RSD < 2.5%, R2: 0.998) and the setup was applied for studying the in-vitro metabolism of methadone by rat liver microsomes. As the metabolic reaction proceeded, methadone and its metabolites were extracted and analyzed in parallel by LC-MS using either isocratic or gradient elution. Compared to a conventional in-vitro metabolism analysis based on protein precipitation followed by LC-MS analysis the fully automated EME-LC-MS system offers a significant time saving and in addition demonstrates increased sensitivity as the analytes were automatically enriched during the extraction process. The experiment revealed 6 to 16 times higher S/N ratios of the EME-LC-MS method compared to protein precipitation followed by LC-MS and thus concomitantly lower LOD and LOQ. The setup integrates a complete analytical workflow of rapid extraction, enrichment, separation and detection of analytes in a fully automated manner. These attributes make the developed system a powerful alternative approach for a wide range of analytical applications.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 905, 28 January 2016, Pages 93–99
نویسندگان
, , , , , , ,