کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1164432 1491024 2014 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Characterization of polysorbate 85, a nonionic surfactant, by liquid chromatography vs. ion mobility separation coupled with tandem mass spectrometry
ترجمه فارسی عنوان
تعیین پلیسوربات 85، یک سوراخ واکنش غیر آلی، توسط کروماتوگرافی مایع در مقابل جداسازی تحرک یون همراه با طیف سنجی جرمی دو طرفه
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• Liquid chromatography (LC) separates amphiphilic blends according to hydrophobicity.
• Ion mobility (IM) spectrometry separates these blends based on molecular size/shape.
• LC–MS provides the separation resolution needed for quantifying fatty acid content.
• IM–MS enables rapid, solvent-free separation and the detection of trace components.
• With either method, tandem MS allows to count the hydrophobic substituents.

Liquid chromatography (LC) and ion mobility (IM) separation have been coupled with mass spectrometry (MS) and tandem mass spectrometry (MS2) to characterize a commercially important nonionic surfactant, polysorbate 85. The constituents of this amphiphilic blend contained a sorbitan or isosorbide core that was chain extended with poly(ethylene oxide) (PEO) and partially esterified at the PEO termini with oleic acid or, to a lesser extent, other fatty acids. Using interactive LC in reverse-phase mode, the oligomers of the surfactant were separated according to their hydrophobicity/hydrophilicity balance. On the other hand, IM spectrometry dispersed the surfactant oligomers by their charge and collision cross section (i.e. size/shape). With either separation method, an increased number of fatty ester groups and/or lack of the polar sorbitan (or isosorbide) core led to higher retention/drift times, enabling the separation of isobaric species or species with superimposed isotope patterns, so that their ester content could be conclusively identified by MS2. LC–MS and IM–MS permitted the detection of several byproducts besides the major PEO-sorbitan oleate oligomers. LC–MS provides the separation resolution needed for quantitative determination of the degree of esterification. IM–MS, which minimizes analysis time and solvent use, is ideally suitable for a fast, qualitative survey of samples differing in their minor constituents or impurities.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 808, 15 January 2014, Pages 83–93
نویسندگان
, , ,