کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1202896 1493562 2014 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Rapid determination of the isomeric truxillines in illicit cocaine via capillary gas chromatography/flame ionization detection and their use and implication in the determination of cocaine origin and trafficking routes
ترجمه فارسی عنوان
تعریف سریع ترکسیلین های ایزومر در کوکائین غیرقانونی از طریق تشخیص کروماتوگرافی گازهای مویرگی / تشخیص یونیزاسیون شعله و استفاده و دلالت آنها در تعیین منشا کوکائین و مسیرهای قاچاق
کلمات کلیدی
کوکائین، ترکسیلین، کروماتوگرافی گاز / تشخیص یونیزاسیون شعله، تعیین منبع، پروفایل نامطلوب
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• GC/FID methodology was developed to quantitate the naturally occurring isomeric truxillines found in cocaine.
• Isomeric truxillines were directly reduced and derivatized which greatly decreased sample preparation and analysis time.
• GC/FID results were more consistent in comparison to data obtained by the previously implemented GC/ECD method.
• Truxillines are an important factor considered in cocaine origin determination.

The isomeric truxillines are a group of minor alkaloids present in all illicit cocaine samples. The relative amount of truxillines in cocaine is indicative of the variety of coca used for cocaine processing, and thus, is useful in source determination. Previously, the determination of isomeric truxillines in cocaine was performed with a gas chromatography/electron capture detection method. However, due to the tedious sample preparation as well as the expense and maintenance required of electron capture detectors, the protocol was converted to a gas chromatography/flame-ionization detection method. Ten truxilline isomers (alpha-, beta-, delta-, epsilon-, gamma-, omega, zeta-, peri-, neo-, and epi-) were quantified relative to a structurally related internal standard, 4′,4″-dimethyl-α-truxillic acid dimethyl ester. The method was shown to have a linear response from 0.001 to 1.00 mg/mL and a lower detection limit of 0.001 mg/mL. In this method, the truxillines are directly reduced with lithium aluminum hydride and then acylated with heptafluorobutyric anhydride prior to analysis. The analysis of more than 100 cocaine hydrochloride samples is presented and compared to data obtained by the previous methodology. Authentic cocaine samples obtained from the source countries of Colombia, Bolivia, and Peru were also analyzed, and comparative data on more than 23,000 samples analyzed over the past 10 years with the previous methodology is presented.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1364, 17 October 2014, Pages 234–240
نویسندگان
, ,