کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1217215 967073 2011 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Gas chromatography–tandem mass spectrometry assay for the quantification of four benzodiazepines and citalopram in eleven postmortem rabbit fluids and tissues, with application to animal and human samples
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Gas chromatography–tandem mass spectrometry assay for the quantification of four benzodiazepines and citalopram in eleven postmortem rabbit fluids and tissues, with application to animal and human samples
چکیده انگلیسی

Pharmacokinetic studies and postmortem toxicological investigations require a validated analytical technique to quantify drugs on a large number of matrices. Three-step liquid/liquid extraction with online derivatization (silylation) ahead of analysis by gas chromatography–tandem mass spectrometry was developed and validated on rabbit specimens in order to quantify citalopram and 4 benzodiazepines (diazepam, nordazepam, oxazepam and temazepam) in 11 biological matrices (blood, urine, bile, vitreous humor, liver, kidney, skeletal muscle, brain, adipose tissue, bone marrow (BM) and lung). Since the 11 biological matrices came from the same animal species, full validation was performed on 1 matrix, bone marrow (considered the most complex), while the other 10 underwent partial validation. Due to non-negligible matrix effects, calibration curves were performed on each matrix. Within-day and between-day precision (less than 12.0% and 12.6%, respectively) and accuracy (from 88.9% to 106.4%) were acceptable on BM at both low and high concentrations. Assessment on the other matrices confirmed accuracy and within-day precision (less than 12%, and generally between 85.1% and 114.5%, respectively). The lower limit of quantification of the method was 1 ng/g for nordazepam, 5 ng/g for citalopram and 10 ng/g for oxazepam, diazepam and temazepam. The combination of 3-step extraction and MS/MS detection provided good selectivity in all matrices, including the most lipid-rich. Application to real-case samples showed that the method was sensitive enough to describe distribution patterns in an animal experiment, and specific enough to detect molecules in highly putrefied samples from human postmortem cases.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography B - Volume 879, Issue 27, 1 October 2011, Pages 2909–2918
نویسندگان
, , , , , , ,