عنوان انگلیسی مقاله ISI
Development and validation of different methods manipulating zero order and first order spectra for determination of the partially overlapped mixture benazepril and amlodipine: A comparative study
ترجمه فارسی عنوان
توسعه و اعتبارسنجی روشهای مختلف دستکاری صفر و طیف اول مرتبه برای تعیین ترکیب مخلوط بخشی بنازپریل و آملودیپین: یک مطالعه مقایسه ای
کلمات کلیدی
بنازپریل، آملودیپین، ثبات نشان می دهد، فاکتور جذب، ضریب ثابت همراه با عبور صفر مشتق شده
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• Comparison between zero and first order spectra.
• The reported methods need sophisticated and expensive instruments and reagents.
• First spectrophotometric stability indicating method for Benazepril determination.
• The good recovery and accuracy makes it applicable in quality control laboratories.

Three simple, selective, and accurate spectrophotometric methods have been developed and then validated for the analysis of Benazepril (BENZ) and Amlodipine (AML) in bulk powder and pharmaceutical dosage form. The first method is the absorption factor (AF) for zero order and amplitude factor (P-F) for first order spectrum, where both BENZ and AML can be measured from their resolved zero order spectra at 238 nm or from their first order spectra at 253 nm. The second method is the constant multiplication coupled with constant subtraction (CM-CS) for zero order and successive derivative subtraction-constant multiplication (SDS-CM) for first order spectrum, where both BENZ and AML can be measured from their resolved zero order spectra at 240 nm and 238 nm, respectively, or from their first order spectra at 214 nm and 253 nm for Benazepril and Amlodipine respectively. The third method is the novel constant multiplication coupled with derivative zero crossing (CM-DZC) which is a stability indicating assay method for determination of Benazepril and Amlodipine in presence of the main degradation product of Benazepril which is Benazeprilate (BENZT). The three methods were validated as per the ICH guidelines and the standard curves were found to be linear in the range of 5–60 μg/mL for Benazepril and 5–30 for Amlodipine, with well accepted mean correlation coefficient for each analyte. The intra-day and inter-day precision and accuracy results were well within the acceptable limits.