کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1231364 1495206 2016 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Novel pure component contribution, mean centering of ratio spectra and factor based algorithms for simultaneous resolution and quantification of overlapped spectral signals: An application to recently co-formulated tablets of chlorzoxazone, aceclofenac an
ترجمه فارسی عنوان
سهم مولفه های خالص رمان، میانگین محاسبه طیف های نسبت و الگوریتم های مبتنی بر عامل برای حل وضوح همزمان و اندازه گیری سیگنال های طیفی همپوشانی: کاربردی به قرص های اخیر قرص کلرزاز اکسازون، آکلوفناک و
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• Novel determination of chlorzoxazone, aceclofenac and paracetamol.
• Spectral resolution was achieved by novel PCCA, MCR and PLS.
• The methods were successfully applied for two different formulations.
• They are simple, less expensive and less time consuming compared to HPLC.

In this work, resolution and quantitation of spectral signals are achieved by several univariate and multivariate techniques. The novel pure component contribution algorithm (PCCA) along with mean centering of ratio spectra (MCR) and the factor based partial least squares (PLS) algorithms were developed for simultaneous determination of chlorzoxazone (CXZ), aceclofenac (ACF) and paracetamol (PAR) in their pure form and recently co-formulated tablets. The PCCA method allows the determination of each drug at its λmax. While, the mean centered values at 230, 302 and 253 nm, were used for quantification of CXZ, ACF and PAR, respectively, by MCR method. Partial least-squares (PLS) algorithm was applied as a multivariate calibration method. The three methods were successfully applied for determination of CXZ, ACF and PAR in pure form and tablets. Good linear relationships were obtained in the ranges of 2–50, 2–40 and 2–30 μg mL− 1 for CXZ, ACF and PAR, in order, by both PCCA and MCR, while the PLS model was built for the three compounds each in the range of 2–10 μg mL− 1. The results obtained from the proposed methods were statistically compared with a reported one. PCCA and MCR methods were validated according to ICH guidelines, while PLS method was validated by both cross validation and an independent data set. They are found suitable for the determination of the studied drugs in bulk powder and tablets.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy - Volume 163, 15 June 2016, Pages 89–95
نویسندگان
, , , ,