کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1240110 1495731 2011 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Flow injection-chemical vapor generation atomic fluorescence spectrometry hyphenated system for organic mercury determination: A step forward
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Flow injection-chemical vapor generation atomic fluorescence spectrometry hyphenated system for organic mercury determination: A step forward
چکیده انگلیسی

Monomethylmercury and ethylmercury were determined on line using flow injection-chemical vapor generation atomic fluorescence spectrometry without neither requiring a pre-treatment with chemical oxidants, nor UV/MW additional post column interface, nor organic solvents, nor complexing agents, such as cysteine. Inorganic mercury, monomethylmercury and ethylmercury were detected by atomic fluorescence spectrometry in an Ar/H2 miniaturized flame after sodium borohydride reduction to Hg0, monomethylmercury hydride and ethylmercury hydride, respectively. The effect of mercury complexing agent such as cysteine, ethylendiaminotetracetic acid and HCl with respect to water and Ar/H2 microflame was investigated.The behavior of inorganic mercury, monomethylmercury and ethylmercury and their cysteine-complexes was also studied by continuous flow-chemical vapor generation atomic fluorescence spectrometry in order to characterize the reduction reaction with tetrahydroborate. When complexed with cysteine, inorganic mercury, monomethylmercury and ethylmercury cannot be separately quantified varying tetrahydroborate concentration due to a lack of selectivity, and their speciation requires a pre-separation stage (e.g. a chromatographic separation). If not complexed with cysteine, monomethylmercury and ethylmercury cannot be separated, as well, but their sum can be quantified separately with respect to inorganic mercury choosing a suitable concentration of tetrahydroborate (e.g. 10− 5 mol L− 1), thus allowing the organic/inorganic mercury speciation.The detection limits of the flow injection-chemical vapor generation atomic fluorescence spectrometry method were about 45 nmol L− 1 (as mercury) for all the species considered, a relative standard deviation ranging between 1.8 and 2.9% and a linear dynamic range between 0.1 and 5 μmol L− 1 were obtained. Recoveries of monomethylmercury and ethylmercury with respect to inorganic mercury were never less than 91%. Flow injection-chemical vapor generation atomic fluorescence spectrometry method was validated by analyzing the TORT-1 certificate reference material, which contains only monomethylmercury, and obtaining 83 ± 5% of monomethylmercury recovered, respectively. This method was also applied to the determination of monomethylmercury in saliva samples.


► Monomethylmercury and ethylmercury were determined on line using FI-CVG-AFS.
► No oxidation to HgII is required for MeHg and EtHg determination.
► No complexing agents are needed for their conversion to volatile species detectable by AFS.
► LOD was about 45 nmol L− 1 (as mercury) for all the species considered.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Spectrochimica Acta Part B: Atomic Spectroscopy - Volume 66, Issues 11–12, November–December 2011, Pages 799–804
نویسندگان
, , , , , ,