کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1268591 1496930 2011 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Sensitive lactate determination based on acclimated mixed bacteria and palygorskite co-modified oxygen electrode
موضوعات مرتبط
مهندسی و علوم پایه شیمی الکتروشیمی
پیش نمایش صفحه اول مقاله
Sensitive lactate determination based on acclimated mixed bacteria and palygorskite co-modified oxygen electrode
چکیده انگلیسی

A sensitive bacteria biosensor was prepared for the detection of trace lactate. The sensitive bioelement, Lactobacillus bulgaricus and Streptococcus thermophilus mixed cultrue, and palygorskite, a perfect matrix for bacteria, was co-immobilized on the surface of oxygen electrode. The biosensor possesses fine selective specificity, good sensitivity and longer operational life time, which were due to the mutual help relationship of symbiotic bacteria and 240 days acclimation with lactate as the carbon source. Hydrodynamic amperometry, an advanced electrochemical method, is suitable for on-line monitoring the concentration change of dissolved oxygen that is closely accompanied with the metabolism of lactate. Electrochemical data show that the current is very sensitive to the changes of the concentration of lactate. The response current was linear with lactic acid concentration in the range from 0 to 300 μmol L− 1, where the response time is no more than 240 s (R = 0.9952), and the sensitivity was 1.87 mA mol− 1 L. Experiments show the biosensor is also very useful for long time on-line monitoring of lactate, such as fermentation progress.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Bioelectrochemistry - Volume 80, Issue 2, February 2011, Pages 151–154
نویسندگان
, ,