• The pH of TEMPOL electrolyte greatly affects the reversibility of its redox reaction.
• Reaction of TEMPOL with OH− ion causes the decrease of electrolyte pH.
• TEMPOL in an acidic electrolyte leads to a decrease in its concentration.
Electrochemical and UV-VIS measurements demonstrate that the pH value of a 4-hydroxy-2,2,6,6-tetramethyl-1-pipperidinyloxyl (TEMPOL) electrolyte significantly impacts its redox reversibility. The diffusion coefficient and kinetic rate constant of TEMPOL in neutral aqueous solution are determined and shown to be comparable to those of vanadium ions used for industrially utilized redox flow batteries (RFBs). RFBs that incorporate a TEMPOL catholyte and Zn-based anolyte have an average voltage of 1.46 V and an energy efficiency of 80.4% during the initial cycle, when subject to a constant current of 10 mA cm−2. We demonstrate several factors that significantly influence the concentration and capacity retention of TEMPOL upon cycling; namely, pH and atmospheric gases dissolved in electrolyte. We expand upon the known reactions of TEMPOL in aqueous electrolyte and propose several concepts to improve its electrochemical performance in a RFB. Controlling these factors will be the key to enable the successful implementation of this relatively inexpensive and environmentally friendly battery.
Figure optionsDownload as PowerPoint slide
Journal: Journal of Power Sources - Volume 321, 30 July 2016, Pages 126–134