کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1420360 1398058 2016 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Internal adaptation of resin composites at two configurations: Influence of polymerization shrinkage and stress
ترجمه فارسی عنوان
سازگاری داخلی کامپوزیت رزین در دو حالت: تاثیر انقباض پلیمریزاسیون و استرس
موضوعات مرتبط
مهندسی و علوم پایه مهندسی مواد بیومتریال
چکیده انگلیسی


• Internal adaptation in a high C-factor cavity was inferior to that in a low C-factor cavity for both conventional and bulk-filled composites.
• Internal adaptation, polymerization shrinkage, and stress were different among composite resin materials.
• Polymerization stress under the compliance-allowed condition showed significant correlations with internal adaptations in high and low C-factor cavities.
• Polymerization stress under the zero-compliance condition did not show a significant correlation with internal adaptation in the low C-factor cavity.

ObjectiveThis study compared internal adaptation of composites under different C-factors and examined the relationship between internal adaptation and polymerization shrinkage parameters.MethodsCylindrical cavities 3 mm in diameter were prepared in 100 human third molars in two depths: 4 mm high C-factor (H-CF) or 1 mm low C-factor (L-CF). After adhesive application (Clearfil SE One, Kuraray Noritake), the composite was placed in two increments in three subgroups: Filtek Supreme (FS, 3 M ESPE); Charisma Diamond (CD, Heraeus Kulzer); Amelogen Plus (AP, Ultradent); and as a single increment in two subgroups: Tetric EvoCeram Bulk Fill (TB, Ivoclar Vivadent) and Venus Bulk Fill (VB, Heraeus Kulzer). After thermo-mechanical load-cycles, imperfect margin percentage (%IM) was calculated using swept-source optical coherence tomography (SS-OCT) imaging. The relationships between %IM and linear shrinkage (LS) and shrinkage stress, measured under either zero-compliance (PS0) or compliance-allowed (PS) conditions were evaluated.ResultsThe %IM was significantly different between H-CF and L-CF groups. The %IM in H-CF turned out to be as groups CD, FS ≤ TB < AP, VB. The %IM in L-CF showed as groups CD, TB ≤ FS, AP < VB. There were significant correlations between shrinkage parameters and %IM, except between PS0 and %IM in L-CF.SignificanceInternal adaptation in a high C-factor cavity was inferior to that in a low C-factor cavity for both conventional and bulk-filled composites. Internal adaptation, polymerization shrinkage, and stress were different among composite materials. Polymerization stress under the compliance-allowed condition showed significant correlations with internal adaptations in high and low C-factor cavities.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Dental Materials - Volume 32, Issue 9, September 2016, Pages 1085–1094
نویسندگان
, , , ,