کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1740776 1521768 2014 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Effect of void fraction covariance on relative velocity in gas-dispersed two-phase flow
ترجمه فارسی عنوان
اثر کوواریانس کسری خالی بر سرعت نسبی در جریان دو فاز گاز پراکنده
کلمات کلیدی
دو مدل مایع، سرعت نسبی، کوواریانس، کسری خالی، مدل راندگی شار دو گروه، جریان پایین
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
چکیده انگلیسی


• Improvement of the area-averaged local relative velocity in gas-dispersed flow.
• Covariance effect in area-averaging total, group-1, and group-2 void fraction.
• Void fraction covariance studied with database of upward, downward adiabatic flows.
• Easily implemented correlations proposed for important void fraction covariances.

In the two-fluid model the dependence between the phases is given in the field equations by interaction terms which become a key focus for improving the overall model performance. Of the interfacial terms in the one-dimensional two-fluid model, the most important is the constitutive relation for the interfacial momentum transfer, specifically the steady-state drag force. The one-dimensional steady-state drag force is a function of area-averaged local relative velocity. This area-averaged local relative velocity can be derived from the drift-flux general expression and the relation between drift velocity and relative velocity. However, due to area averaging there is a void fraction covariance which current and past researchers have assumed to be one. Similarly, in the one-dimensional modified two-fluid model which divides the gas phase into two-groups (i.e. spherical/distorted bubbles as group-1, and cap/slug/churn-turbulent bubbles as group-2) the group-1 and group-2 area-averaged local relative velocity is required for the group-1 and group-2 steady-state drag force. These relative velocities introduce three covariance terms: group-1 void fraction, group-2 void fraction, and an inter-group covariance between group-1 and group-2 void fraction. The covariance terms have been analyzed with a substantial database from the literature including upward flow in pipe diameters of 1.27 cm–15.2 cm, downward flow in pipe diameters of 2.54 cm and 5.08 cm, and upward flow in a 1.90 cm hydraulic diameter annulus channel. Simple relations are proposed to specify the covariance in order to improve the prediction of area-averaged local relative velocity in the classical two-fluid model and the modified two-fluid model. These relations are shown to have good agreement with the experimental data in predicting the effect on the area-average relative velocity with an average relative error of 5% over the data range.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Progress in Nuclear Energy - Volume 70, January 2014, Pages 209–220