کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1762509 1019698 2008 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Encapsulation of Concentrated Protein Into Erythrocyte Porated by Continuous-Wave Ultrasound
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم آکوستیک و فرا صوت
پیش نمایش صفحه اول مقاله
Encapsulation of Concentrated Protein Into Erythrocyte Porated by Continuous-Wave Ultrasound
چکیده انگلیسی
A procedure of continuous-wave ultrasound (US)-induced hemolysis and reseal in solution containing water soluble protein was applied to a method for encapsulating concentrated protein solutions into resealed rat erythrocyte ghosts. To find a condition yielding a higher mean corpuscular concentration of encapsulated protein (MCC), we investigated the value of MCCs for various conditions. Additions of a small amount of plasma, Ca2+ and Mg2+ significantly increased MCC, whereas these additives did not alter the degree of hemolysis. It was suggested that plasma protect the molecular damages by the US, and that Ca2+ and Mg2+ physically stabilized the lipids of the erythrocyte membrane to fuse and reseal the pore induced by US. A maximal MCC of ∼50 mg/mL, which is 2.5 times the reported maximum amount encapsulated by the osmotic dialysis method, was obtained without a blood-washing procedure. (E-mail: masaaki.iino@it-chiba.ac.jp)
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Ultrasound in Medicine & Biology - Volume 34, Issue 12, December 2008, Pages 1924-1933
نویسندگان
, , , ,