چکیده انگلیسی

The aim of this study was to evaluate the ability of near-infrared chemical imaging (NIR-CI), near-infrared (NIR), Raman and attenuated-total-reflectance infrared (ATR-IR) spectroscopy to quantify three polymorphic forms (I, II, III) of furosemide in ternary powder mixtures. For this purpose, partial least-squares (PLS) regression models were developed, and different data preprocessing algorithms such as normalization, standard normal variate (SNV), multiplicative scatter correction (MSC) and 1st to 3rd derivatives were applied to reduce the influence of systematic disturbances. The performance of the methods was evaluated by comparison of the standard error of cross-validation (SECV), R2, and the ratio performance deviation (RPD). Limits of detection (LOD) and limits of quantification (LOQ) of all methods were determined. For NIR-CI, a SECVcorr-spec and a SECVsingle-pixel corrected were calculated to assess the loss of accuracy by taking advantage of the spatial information. NIR-CI showed a SECVcorr-spec (SECVsingle-pixel corrected) of 2.82% (3.71%), 3.49% (4.65%), and 4.10% (5.06%) for form I, II, III. NIR had a SECV of 2.98%, 3.62%, and 2.75%, and Raman reached 3.25%, 3.08%, and 3.18%. The SECV of the ATR-IR models were 7.46%, 7.18%, and 12.08%. This study proves that NIR-CI, NIR, and Raman are well suited to quantify forms I–III of furosemide in ternary mixtures. Because of the pressure-dependent conversion of form II to form I, ATR-IR was found to be less appropriate for an accurate quantification of the mixtures. In this study, the capability of NIR-CI for the quantification of polymorphic ternary mixtures was compared with conventional spectroscopic techniques for the first time. For this purpose, a new way of spectra selection was chosen, and two kinds of SECVs were calculated to achieve a better comparability of NIR–CI to NIR, Raman, and ATR-IR.

Figure optionsDownload high-quality image (143 K)Download as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: European Journal of Pharmaceutics and Biopharmaceutics - Volume 84, Issue 3, August 2013, Pages 616–625
نویسندگان
, , , , , ,