کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
267323 504399 2013 13 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Two-plastic-hinge and two dimensional finite element models for post-tensioned precast concrete segmental bridge columns
موضوعات مرتبط
مهندسی و علوم پایه علوم زمین و سیارات مهندسی ژئوتکنیک و زمین شناسی مهندسی
پیش نمایش صفحه اول مقاله
Two-plastic-hinge and two dimensional finite element models for post-tensioned precast concrete segmental bridge columns
چکیده انگلیسی

Recent studies have confirmed that unbonded post-tensioned (PT) precast concrete segmental bridge columns are capable of undergoing large lateral deformation with negligible residual drift. To provide a clear guideline for the modeling of the columns for practicing engineers as well as researchers, this paper presents two types of numerical models: (i) a two-plastic-hinge model using the sectional moment–curvature analysis procedure at two segment interfaces and (ii) a two-dimensional (2D) finite element model using truss and beam-column elements in the computer program PISA. Three unbonded PT precast concrete-filled tube segmental bridge column specimens are cyclically tested. Two specimens have mild steel bars crossing to different column heights for studying the effects of anchorage position on the hysteretic energy dissipation (ED) capacity. The test results show that (1) the mild steel bars (“ED bars”) can increase hysteretic energy dissipation, and Specimens 1–3 have equivalent viscous damping of 6.5–8.8%, (2) a plastic hinge length in the first or second segment varies with anchorage position of ED bars and lateral displacement, and (3) an equivalent unbonded length along which the strain in the ED bar is assumed uniformly distributed on each of the two sides is 5–6 bar diameter. A 2D finite-element model is utilized to predict the cyclic behavior of the specimens. Parametric studies using finite-element models are also conducted to investigate the effects of ED bar area, initial strand force, and aspect ratio on the cyclic behavior.


► Two methods were developed for predicting the behavior of PT segmental bridge columns.
► Three PT precast concrete segmental bridge columns were cyclically tested.
► Two specimens had mild steel bars crossing to different column heights.
► Parametric studies were conducted to investigate the cyclic behavior of PT segmental bridge columns.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Engineering Structures - Volume 46, January 2013, Pages 205–217
نویسندگان
, , ,